When the grid fails, operations need backup.

Mobile three-phase backup power for critical infrastructure. Built for rapid deployment in locations with limited access and quiet, fuel-free battery operation.

Three-phase power · up to 12 kW output · up to 40 kWh storage · UPS transfer time < 10 ms
Specifications vary by configuration.

Best for off-grid operation, backup power during outages and rapid field deployment.
Developed for Institute of Security Studies (I-B-S), a Czech institute for security studies.

What is FUP?

“A mobile hybrid power system with battery backup for demanding environments. when the power fails, it takes over the connected backup circuits.“

A power outage can trigger a chain of failures.

A blackout, cyberattack or natural disaster can disrupt electricity supply and put connected services at risk.

> Water: Loss of pressure and disruption to drinking-water supply.
> Telecoms: Communication outages and reduced visibility for control centres.
> Transport: Failed signalling and disrupted services.
> Healthcare: Power loss affecting equipment, refrigeration and lighting.
> Crisis management: Loss of communications when they are needed most.

Diesel generator runtime depends on fuel reserves and load. If supplies are disrupted, the backup source itself can become a weak point.

One node. Four sources. Quiet backup.

> FUP is a mobile hybrid power node for critical infrastructure backup.

> It combines three-phase power, battery storage and integrated distribution. Transfer to backup power in less than 10 ms helps bridge outages. The system can use the grid, battery, solar panels or a generator, depending on availability.

> More power options. No cloud dependency. Less reliance on continuous generator operation.

The generator provides power.
FUP adds intelligent control
and battery backup.

HYBRID ARCHITECTURE

Four sources. Two types of output.

Grid supply
Battery storage
Generator
Solar panels
Battery-backed output
Grid-only output

Automatic source management based on configured priorities.

The battery bridges power interruptions. With a compatible connection and configuration, the generator starts as needed, reducing fuel consumption and noise.

> Easy connection: 16 A or 32 A sockets make it easy to connect compatible equipment. The wheeled design allows the unit to be moved into position.
> Expandable storage: Add battery modules for longer runtime, depending on the selected configuration.

View technical specifications

Designed for operational continuity

5 reasons to choose FUP.

> Battery standby: Backup without storing fuel for the battery unit itself. Carry out inspections and maintenance in accordance with the documentation.
> Mobile design: A width of 75 cm makes it easier to move into confined spaces. Assess the access route and lift capacity for the particular site.
> Three-phase power: For compatible pumps, variable-frequency drives, HVAC equipment, SCADA systems and servers within the selected configuration’s power limits.
> Silent & Emission-Free: Quiet power without a running combustion engine. Installation must meet the unit’s operating requirements.
> Offline operation: Operation without cloud dependency reduces the need for external data connectivity.

Why conventional backup may not be enough

A mobile solution between a portable battery station and a large generator.

Portable power stations

Many portable stations offer only single-phase output and limited power for demanding equipment.

Diesel generators

They require fuel, regular checks and suitable arrangements for heat and exhaust gases. Noise and size can restrict where they can be used.

FUP Systems

A mobile three-phase hybrid system with battery backup. It combines available power sources to suit operational needs.

Downtime is more than a technical problem. IT’S A BILL.

Every minute without power can mean operational losses and safety risks.

€7,000 / min

Healthcare & continuity of care

An outage can disrupt equipment, delay planned procedures and put blood or medicine storage at risk.
Source: Censinet, 2024

€300K+ / hr

Critical infrastructure & public services

A waterworks, wastewater plant or control centre outage can affect an entire area and hinder emergency response.
Source: ITIC 2024 · Splunk/Oxford Economics 2025

~24 hrs

Fuel-dependent backup

A generator stops when fuel is unavailable. Combining a battery with other sources provides more options for maintaining power.
Your own field-proven figure

_Compare the cost of backup with the impact of an outage on your operations_
We can help you select a suitable configuration.

Operational continuity as part of resilience

Backup power can be one of the measures supporting business continuity under NIS2. Purchasing FUP alone does not ensure compliance with all requirements of the Directive.

> Backup for essential loads: A UPS transfer time of less than 10 ms helps bridge power interruptions.
> No cloud dependency: An offline configuration to suit your organisation’s needs.
> Multiple energy sources: Battery, grid, solar panels and generator support planning for different outage scenarios.
> Repairability and documentation: An architecture based on commercially available components supports servicing and long-term maintenance.
_Q: What role does backup power play in your business continuity plan?_

key specs

The numbers that matter.

Output: 6 / 8 / 10 / 12 kW · 2× peak for 10s
Storage: 10 / 15 kWh LiFePO4 · +25 kWh extension
Solar Input: From 2 kWp up to 15,6 kWp
Outlets: 3× 400V + 6× 230V (4 backed up)
Form Factor: 95 x 100 x 75 cm width – fits standard doors
Weight: 280 kg (6kW/10kWh) — lifts with 4 people
UPS Transfer: < 10 ms
Oper. Temp: -20 – +50 °C (Sheltered deployment in winter)
Lifespan: 5–20 years
Ruggedness: Built to be dropped, rolled, and abused.

Fail-Safe Design: Designed to vent smoke safely, avoiding the catastrophic explosions typical of diesel tanks.
Datasheet FUP 3P10

Rapid deployment

From transport to operation in a few steps. No tools required.

0:00 Unload (Forklift/Crane/Hands)
0:30 Position & Brake
1:30 Ground (M8 rod)
2:30 Connect Inputs (Grid/Gen/PV)
3:00 Running & Powering Loads
Operator training takes under 15 minutes.

Use cases

Where FUP helps keep operations running

Water & wastewater
Power for compatible three-phase pumps, variable-frequency drives and SCADA telemetry, including remote reservoirs without a fixed generator.
Telecom & data nodes
Backup power for base stations and optical nodes. Runtime depends on the load and battery capacity.
Rail & transport
Backup for compatible signalling and digital systems. The configuration must be assessed against the requirements of the specific equipment.
Healthcare & field care
Power for compatible medical equipment, blood and medicine refrigeration, and task lighting in line with the facility’s requirements.
Crisis command centres
A mobile UPS for communications, servers and displays. The unit can be relocated when the site changes.
Perimeter & strategic sites
Backup for cameras, electronic locks and infrared barriers when the main power supply fails.
Our philosophy

“If it breaks in the field, it must be possible to repair it in the field.“

Designed for demanding conditions

If it survived the front, it will survive your blackout.

> 24 months of continuous field deployment
> Ongoing NATO / AFU certification
> COTS architecture — repairable with standard parts, no vendor lock-in
> Trusted by the relevant institutions
Strengthen the resilience of your infrastructure.

Talk to us. →

Book a consultation

Developed in the Czech Republic for Institut Bezpečnostních Studií, z. ú. © 2026 I-B-S
© 2026 FUP / Forever under Power